Abcess Excision with the Sapphire Portable Diode Laser
Tip: Initiated
Mode: Continuous Wave
Power: 1.0 W
Anesthesia: Topical or Local, as required
Technique: Contact
1. Determine the status of the lesion, chronic or acute, and
select a site to enter the parulis of the infection.
2. Based on the lesion status, enter the lesion by placing the
ber tip at the most coronal spot on the parulis and with short
strokes, make an incision to establish a drainage path.
3. Using high volume suction, irrigate the area with saline
solution as the exudate appears.
4. Insert the tip into the incision site without emitting energy and
lightly probe the area inside the parulis as you advance the
tip apically.
5. Once you have established the base of the parulis, back the
ber optic (therapy) tip out approximately 2 mm and activate
the Sapphire Portable Laser as you slowly withdraw the tip.
6. Remove the tip briefl y and allow any exudate to drain.
7. After draining has slowed, re-enter the parulis and insert the
Fiber Optic Tip just short of the base and then withdraw
the Tip as the laser is activated.
8. Repeat the process until you have established a clear path for
completing the remaining drainage.
9. Administer oral antibiotics as needed and give the patient
instructions on using warm saline to cleanse and irrigate
the oral environment.
10. If you are not able to complete the drainage procedure
without pain, review basic protocols before administering a
local anesthetic into the infected area.